Produits Registres d'Air

Product Code: CEI-VCD / VCD-OB / VCD-PB

Volume Control Registres

Valve Contrôle dans الDébit

Manual ou moteurized volume control dampers regulating airflow in duct systems. GI, AL ou SS frames. Opposed-blade ou parallel-blade configurations pour different pressure requirements.

Question rapide ? WhatsApp →
ISO 9001:2015SMACNADW144
Description

Product Description

Castle Volume Control Registres regulate et balance airflow within HVAC duct systems. Available in opposed blade (OB) et parallel blade (PB) configurations. Le frame is constructed de galvanized steel avec extruded aluminium aerofoil double-skinned blades pour low-leakage performance. Het locking quadrant avec clear open/close indication et three intermediate positions (1/4, 1/2, 3/4). Moteurized actuator option pour BMS integration.

Opposed Blade Design
Provides uniformulaire airflow regulation avec low turbulence — superiou to parallel blade pour balancing applications.
Low Leakage
Foam gasket blade seals et nylon gear linkage minimize air leakage in closed position.
BMS Compatible
Optional moteurized actuator avec BACnet/Modbus protocol pour Building Management System integration.
Heavy Duty Construction
Welded GI frame avec aluminium spray coating on joints — courosion resistant pour long service life.
ISO 9001:2015 Certified
Quality management system certified by IGC, covering all stages de raw material to final delivery.
SMACNA & DW144 Compliant
Manufactured to le latest edition of SMACNA HVAC Duct Construction Standards et DW144.
Custom Sizes Available
Nonn-standard dimensions manufactured to project specifications avec competitive lead times.
Approved by Leading Consultants
Accepted by Dar Al-Handasa, ECG, SYSTRA, Khatib & Alami et 25+ majeurs engineering consultants.
Spécifications

Technical Spécifications

ParameterValueUnit
Frame MaterialGalvanized steel sheet 1.2mm (Z-275)
Frame Depth125mm (standard) / 200mm (slip & clip)mm
Flange Height25mm standard — undrilledmm
Blade MaterialDouble-skinned extruded aluminium aerofoil profiles
Blade OperationOpposed blade (standard) / Parallel blade (option)
Drive ShaftElectro-plated square rod 12.7×12.7mmmm
BushingsSelf-lubricating nylon bushings
Blade LinkageToothed nylon gears — opposed blade operation
HetleGI locking het quadrant — open/close + 3 intermediate positions
Blade SealFoam gasket à travers blade edges — minimizes leakage
Max Size2400×2400mm (with mullions)mm
MountingFlanged / Duct insertion (slip-in)
Moteurized Option24V/230V actuator — 0-10V / On-Off / BACnet
ComplianceSMACNA / AMCA / ASHRAE
Applications

Fields of Application

Duct équilibrage du flux d'air
Zone temperature control
AHU outlet regulation
Testing & commissioning adjustment
BMS-controlled zone dampers
Equipment room ventilation control
Assurance Qualité

Tests & Certificates

ISO Certification

International Quality Certifications

ISO 9001:2015
View
ISO 9001:2015
ISO 14001:2015
View
ISO 14001:2015
OHSAS 18001
View
OHSAS 18001

Normes Internationales

SMACNA · DW144 · IGC · UL

SMACNA
View
SMACNA
DW144
View
DW144
IGC
View
IGC
UL
View
UL

Duct Test

Rigouous leakage et pressure testing to SMACNA et DW144 standards.

Test Conduit 1
View
Test Conduit 01
Test Conduit 2
View
Test Conduit 02
Test Conduit 3
View
Test Conduit 03

Air Tests

Vitesse d'air et distribution testing.

Test d'Air 1
View
Test d'Air 01
Test d'Air 2
View
Test d'Air 02
Obtenir a Devis

Request a Devis