Product Code: CEI-SMD / SMD-M
Smoke Moteurized Registres
Valve Fumée بMoteur
Electrically actuated smoke dampers integrated avec building fire alarm et BMS systems. Fail-safe spring return to closed position on power loss. 24V ou 230V actuator options.
Frame Material
Question rapide ?
WhatsApp →
ISO 9001:2015SMACNADW144
Description
Product Description
Castle Smoke Moteurized Registres are electrically-operated dampers that close upon detection of smoke by le fire alarm system — preventing smoke circulation through HVAC ductwork. Le fail-safe spring-return actuator closes le damper on power loss ou smoke detection signal. Compatible avec all fire alarm et BMS systems via 24V/230V actuators.
Spring-Return Fail-Safe
Actuator closes damper on power loss — guaranteed smoke containment even during electrical failure.
Fire Alarm Integration
Direct connection to fire alarm panel — closes automatically on smoke detection signal.
Low Leakage
Class II leakage per UL 555S — stainless steel jamb seals minimize smoke passage in closed position.
Dual Protection
Thermal probe at 72°C fournit secondary protection independent of fire alarm system.
ISO 9001:2015 Certified
Quality management system certified by IGC, covering all stages de raw material to final delivery.
SMACNA & DW144 Compliant
Manufactured to le latest edition of SMACNA HVAC Duct Construction Standards et DW144.
Custom Sizes Available
Nonn-standard dimensions manufactured to project specifications avec competitive lead times.
Approved by Leading Consultants
Accepted by Dar Al-Handasa, ECG, SYSTRA, Khatib & Alami et 25+ majeurs engineering consultants.
Spécifications
Technical Spécifications
| Parameter | Value | Unit |
|---|---|---|
| Frame Material | Galvanized steel 1.5mm | — |
| Blade Material | Galvanized steel — multi-blade opposed | — |
| Actuator | Spring-return fail-safe — 24V AC/DC ou 230V AC | — |
| Control Signal | On/Off / 0-10V / BACnet / Modbus | — |
| Smoke Rating | ES 60/120 min per BS EN 1366-10 | min |
| Leakage Class | Class II per UL 555S | — |
| Blade Seal | Stainless steel jamb seals + silicone blade seals | — |
| Rectangular Sizes | 150×150 to 1500×1500mm | mm |
| Round Sizes | Ø100 to Ø630mm | mm |
| Thermal Probe | 72°C duct-mounted probe (secondary protection) | °C |
| Mounting | In-duct / Wall / Floou | — |
| Compliance | UL 555S / BS EN 1366-10 / BS EN 13501-4 / NFPA 90A | — |
Applications
Fields of Application
Smoke compartmentation
AHU smoke isolation
Couridou smoke barriers
Stairwell pressurization
Hospital smoke zones
High-rise building smoke control
Assurance Qualité
Tests & Certificates
Duct Test
Rigouous leakage et pressure testing to SMACNA et DW144 standards.

Test Conduit 01

Test Conduit 02

Test Conduit 03
Air Tests
Vitesse d'air et distribution testing.

Test d'Air 01

Test d'Air 02